Skip to Primary Navigation Skip to Site Navigation Skip to Main Content null
Filtrete (TM) Commercial HVAC Filter MERV A15 V-Bank with Gasket

Commercial HVAC Filter MERV A15 V-Bank with Gasket

(MERV 16* Efficiency Rating per ASHRAE 52.2: 2007)

 

Filtrete (TM) Commercial HVAC Filter MERV A15 V-Bank with Gasket

Contributes to earning one point towards LEED (R) certification process.

Product and Performance Data

  •  Available in Standard and Reverse Flow designs
  •  
  •  Electrostatically charged (electret) filter media
  •  
  •  Integral gaskets prevent air-bypass, keeping coils clean
  •  
  •  Efficiency Rating @ 492 fpm (per ASHRAE 52.2: 2007)
  • MERV 16*
  •  Efficiency Rating @ 492 fpm (per ASHRAE 52.2: 2007 Appendix J)
  • MERV A15
  •  Initial pressure drop
  • 0.26" w.g.
  •  Recommended final pressure drop
  • 1.5" w.g.

Typical Applications

Hospitals and Healthcare facilities
  Filtrete Commercial HVAC Filter MERV A15 V-Bank with Gasket for hospitals and healthcare facilities.
Research laboratories
  Filtrete Commercial HVAC Filter MERV A15 V-Bank with Gasket for research laboratories.
Pharmaceutical companies
  Filtrete Commercial HVAC Filter MERV A15 V-Bank with Gasket for pharmaceutical companies.
Clean manufacturing facilities
  Filtrete Commercial HVAC Filter MERV A15 V-Bank with Gasket for clean manufacturing facilities.
Airports
  Filtrete Commercial HVAC Filter MERV A15 V-Bank with Gasket for airports.
Commercial offices
  Filtrete Commercial HVAC Filter MERV A15 V-Bank with Gasket for commercial offices.
Universities / Schools
  Filtrete Commercial HVAC Filter MERV A15 V-Bank with Gasket for universities / schools.

Key Benefits

Some of the key benefits our customers may enjoy when using the Filtrete™ Commercial HVAC Filter MERV A15
V-Bank with Gasket, are the following.

  • Using the filter on all outside air intakes and inside air recirculation returns, the Filtrete™ Commercial HVAC Filter MERV A15 V-Bank with Gasket contributes to earning a point in the LEED certification process for new and existing buildings.
  • The Filtrete™ V-Bank Filters MERV A15 with Gasket meet the Facilities Guidelines Institutes (ANSI / ASHRAE / ASHE Standard 170 - 2008) requirements for hospitals and healthcare facilities where MERV 13 or 14 primary filters are required.
  • Filtrete™ V-Bank Filters have an industry leading low initial pressure drop and may lead to substantial energy savings, when compared to competitive V-Bank or box filters with the same efficiency.
  • Filtrete™ V-Bank Filters have long filter life, due to their unique combination of electret, depth-loading filtration media, precision pleat structure, and high filter media area.
  • Due to their lightweight frame construction, Filtrete™ V-Bank Filters are easier to handle and install than many comparable V-Bank filters and metal box filters. Lighter weight is especially important in facilities where HVAC filters must be manually carried to the site.
  • Factory installed gaskets ensure correct installation and usage of the gaskets, resulting in consistent reduction of air bypass. The factory installed gaskets of Filtrete™ V-Bank Filters eliminate the need for additional labor to install gaskets on-site.
  • Filtrete™ V-Bank Filters are 100% synthetic, resulting in moisture and humidity resistant, corrosion free filters that do not support mold growth.
  • Filtrete™ V-Bank Filters are 100% metal free and fully incinerable.

For more information, please download the product information sheet for the (PDF, 221 Kb). If you would like to learn more about our MERV A13 and MERV A14
V-Bank Filters, please download the (PDF, 276 Kb).

The Filtrete™ Commercial HVAC Filter MERV A15 V-Bank with Gasket is available in 3 different sizes to accommodate filter dimensional needs in most air handling units.

Filter Measurements

Filtrete (TM) Commercial HVAC V-Bank Filter Measurements - Standard Flow

For questions or to place an order
in the U.S., please contact our
Customer Service at
(800) 648-3550 or (651) 789-7381.

Standard Flow V-Bank

Product
No.

3M ID Number
 

Nominal Dimensions
"A" x "B" x "C" Inches (mm)

Width "A"
Inches (mm)

Height "B"
Inches (mm)

Depth "C"
Inches (mm)

E739

70-0714-7184-4

24 x 24 x 12 (610 x 610 x 305)

23 3/8 (594)

23 3/8 (594)

11.9 (302)

E740

70-0714-7185-1

24 x 20 x 12 (610 x 508 x 305)

23 3/8 (594)

19 3/8 (492)

11.9 (302)

E741

70-0714-7186-9

24 x 12 x 12 (610 x 305 x 305)

23 3/8 (594)

11 3/8 (289)

11.9 (302)

Filter Measurements

Filtrete (TM) Commercial HVAC V-Bank Filter Measurements - Reverse Flow

 
 
 
 

Reverse Flow V-Bank

Product
No.

3M ID Number
 

Nominal Dimensions
"A" x "B" x "C" Inches (mm)

Width "A"
Inches (mm)

Height "B"
Inches (mm)

Depth "C"
Inches (mm)

E760

70-0714-7206-5

24 x 24 x 12 (610 x 610 x 305)

23 3/8 (594)

23 3/8 (594)

11.9 (302)

E763

70-0714-7209-9

24 x 20 x 12 (610 x 508 x 305)

23 3/8 (594)

19 3/8 (492)

11.9 (302)

E766

70-0714-7212-3

24 x 12 x 12 (610 x 305 x 305)

23 3/8 (594)

11 3/8 (289)

11.9 (302)

* The particle capture efficiency will reduce to the MERV-A reporting value in actual use. Please visit www.whatisMERVA.com for more information.
 
Green Building Council Member
National Air Filtration Association
Energy Star Partner
INDA

3M and Filtrete are trademarks of 3M Company.
All other trademarks are the property of their respective owners.