Skip to Primary Navigation Skip to Site Navigation Skip to Main Content
Biomedical Electrodes > Diaphoretic Monitoring Electrodes > 

3M™ Red Dot™ Diaphoretic Foam Monitoring Electrodes


3M™ Red Dot™ Diaphoretic Foam Monitoring Electrodes
Click to Enlarge

A rectangular-shaped electrode that offers a high-tack adhesive and foam backing designed for diaphoretic clinical situations.

Red Dot electrodes (Cat. Nos. 2230, 2270) have a 3M™ solid gel conductive column and 3M™ SureSeal moisture vapor barrier cap to ensure product freshness. Each electrode also has a border adhesive that works well on moist skin conditions.

This product is not radiolucent.

2270 Red Dot electrodes are available in quantities of 3, 5, or 50 each per bag with an abrader on each electrode.

2230 Red Dot electrodes are available 50 each per bag without an abrader.


Image Catalog # Product Description MSDS
Red Dot Diaphoretic Foam Electrode 2230, 2270   2230   3M™ Red Dot™ Diaphoretic Foam Monitoring Electrode 2230  5,1cm x 5,5cm Diaphoretic Foam Monitoring Electrode, without abrader (50 Each Bag; 20 Bag/Case)  PDF  
Red Dot Diaphoretic Foam Electrode 2230, 2270   2270-3   3M™ Red Dot™ Diaphoretic Foam Monitoring Electrode 2270-3  Diaphoretic Foam Electrode, with abrader (5,1cm x 5,5cm) (3 Each/Bag; 20 Bag/Box; 10 Box/Case).   
Red Dot Diaphoretic Foam Electrode 2230, 2270   2270-5   3M™ Red Dot™ Diaphoretic Foam Monitoring Electrode 2270-5  Diaphoretic Foam Electrode, with abrader (5,1cm x 5,5cm) (5 Each/Bag; 20 Bag/Box; 10 Box/Case).  PDF  
Red Dot Diaphoretic Foam Electrode 2230, 2270   2270-50   3M™ Red Dot™ Diaphoretic Foam Monitoring Electrode 2270-50  5,1cm x 5,5cm Diaphoretic Foam Monitoring Electrode, with abrader (50 Each/Bag; 20 Bag/Case)  PDF  
Benefits

  • Patented solid gel conforms to the skin quickly allowing high-quality, uninterrupted traces.
  • The gel's low chloride content minimizes skin irritation for increased patient comfort.
  • Use of built-in abrader disc improves trace quality for better results.
  • 3M™ diaphoretic adhesive provides greater adhesion to the skin, especially in moist conditions, which results in better trace quality.
  • 3M™ SureSeal Cap Seal prevents premature product dryout to help ensure product freshness for 30 days out of the bag.
  • Foam backing is occlusive to fluids and is easy to handle and remove.

    Suggested Applications

  • General ECG monitoring situations where skin moisture is an issue
  • For use in ER, OR, Stress Test, Cardiac Rehab and Echo-Cardiography departments

    Frequently Asked Questions

    Common Questions - Red Dot Diaphoretic Foam Electrodes - Questions and Answers (PDF 20.3 K)

    Latex Information

    Click Here for Latex Information

    Regulatory Material