Skip to Primary Navigation Skip to Site Navigation Skip to Main Content
Sterilization Assurance Products > Exposure Control Products > 

3M™ Comply™ Instrument Protectors


3M™ Comply™ Instrument Protectors
Click to Enlarge

Designed for inserting into peel pouches, they reduce the potential of pouch puncture, protect the instrument in an open position to permit complete penetration of sterilant, and provide visual assurance that it was exposed to the sterilization process.

3M™ Comply™ 13911, 13913, and 13915 Instrument Protectors are rigid paperboard with clear 2 mil plastic pouches that hold instruments in an unlocked, open position so the sterilant can contact all surfaces during sterilization, protect sharp-pointed surgical instruments from damage, and reduce the chance of peel-pouch puncture during sterilization. Dual chemical indicator bars (Class I process indicators) are printed on paper for steam and EO sterilization monitoring. The steam chemical indicator turns from blue to gray/black and EO chemical indicator turns from yellow to rust/red. The protector is placed into a peel pouch. The chemical indicator is used for both exposure control monitoring (external chemical indicator) and pack control monitoring (internal chemical indicator).


Image Catalog # Product Description MSDS
  13911   3M™ Comply™ Instrument Protectors 13911  2 inch x 5 inch (5,1cm x 12,8cm) Instrument Protectors, Protects sharp pointed surgical instruments from damage and reduces possibility of pouch puncture during sterilization. Indicators on the protectors verify steam or EO processing.  PDF  
Comply Instrument Protectors 13913   13913   3M™ Comply™ Instrument Protectors 13913  3-1/2 inch x 6-5/8 inch (9,9cm x 16,8cm) Instrument Protectors, Protects sharp pointed surgical instruments from damage and reduces possibility of pouch puncture during sterilization. Indicators on the protectors verify steam or EO processing.  PDF  
  13915   3M™ Comply™ Instrument Protectors 13915  5-1/2 inch x 9-1/2 inch (14cm x 24cm) Instrument Protectors, Protects sharp pointed surgical instruments from damage and reduces possibility of pouch puncture during sterilization. Indicators on the protectors verify steam or EO processing.  PDF  
Benefits

  • Externally visible chemical indicators that change color when exposed to sterilant provide assurance of exposure to the sterilization process.
  • Instrument protectors are less expensive than double-peel pouching or adding tips to instruments, providing a more economical alternative for puncture protection.
  • Available in three sizes to accommodate a variety of instrument sizes.
  • Easier to use than double-peel pouches or tips added to instruments to provide convenience and save you time.

    Suggested Applications

  • To monitor sterilization exposure in steam or EO sterilization process.
  • Protecting instruments in place to facilitate sterilant penetration.
  • Guarding against pouch puncture.

    Frequently Asked Questions

    Common Questions - Comply Instrument Protectors - Questions and Answers (PDF 14.7 K)

    Package Insert

    Comply Instrument Protector Package Insert, English - Package Insert (PDF 45.7 K)

    Latex Information

    Click Here for Latex Information

    Regulatory Material