3M™ Comply™ Glutaraldehyde Monitors


3M™ Comply™ Glutaraldehyde Monitors
Click to Enlarge

Chemical monitors that indicate if a glutaraldehyde solution meets the manufacturer's recommendation for a minimum effective concentration (MEC) needed to effectively kill organisms.

Glutaraldehyde chemical monitors are used for equipment control as a way to find out whether or not the glutaraldehyde solution is doing its job or is at the minimum concentration (MEC) needed to effectively kill organisms. Glutaraldehyde solution should be tested prior to immersing medical devices into the solution to ensure that the solution is at its MEC.

3M™ Comply™ 3983MM Glutaraldehyde Monitors

A dip stick type monitor with a chemical indicator pad that changes from white to yellow in the presence of a >1.5% minimum effective concentration (MEC) of glutaraldehyde. If the pad stays white, the glutaraldehyde solution must be discarded. If the pad is yellow, the solution may be used/reused.

3M™ Comply™ 3987 Glutaraldehyde Monitors

A dip stick type monitor with a chemical indicator pad that changes from white to yellow in the presence of a >1.8% minimum effective concentration (MEC) of glutaraldehyde. If the pad stays white, the glutaraldehyde solution must be discarded. If the pad is yellow, the solution may be used/reused.

3M™ Comply™ 3989 Glutaraldehyde Monitors

A dip stick type monitor with a chemical indicator pad that changes from white to yellow in the presence of a >2.1% minimum effective concentration (MEC) of glutaraldehyde. If the pad stays white, the glutaraldehyde solution must be discarded. If the pad is yellow, the solution may be used/reused.


Image Catalog # Product Description MSDS
Comply Glutaraldehyde Monitors 3983   3983MM   3M™ Comply™ Glutaraldehyde Monitors 3983MM  Glutaraldehyde Monitors, Black framed chemical reaction pad turns yellow when above 1.5% MEC concentration  PDF  
Comply Glutaraldehyde Monitors 3983   3987   3M™ Comply™ Glutaraldehyde Monitors 3987  Glutaraldehyde Monitors, Black framed chemical reaction pad turns yellow when above 1.8% MEC concentration  PDF  
Comply Glutaraldehyde Monitors 3983   3989   3M™ Comply™ Glutaraldehyde Monitors 3989  Glutaraldehyde Monitors, Black framed chemical reaction pad turns yellow when above 2.1% MEC concentration  PDF  
Benefits

  • Provides visual indication when glutaraldehyde solution should be replaced, ensuring that only effective solutions are used.
  • Indicator strips are easy to use -- simply dip into solution, and read.
  • Provides fast, easy-to-read results to make quick, accurate decisions.

    Suggested Applications

  • To monitor glutaraldehyde solution minimal effective concentration (MEC).
  • Choose the appropriate glutaraldehyde monitor (i.e., 1.5%, 1.8%, 2.1%) based on the MEC listed in the glutaraldehyde manufacturer's labeling.
  • Chemical indicator pad changes from white to yellow if solution is still effective.

    Regulatory Material