3M™ Fire Barrier Cast-in Device


3M™ Fire Barrier Cast-in Device
Click to Enlarge

The 3M™ Fire Barrier Cast-In Devices are a line of firestopping devices that are installed to firestop combustible and non-combustible pipe and cable penetrations through concrete floor assemblies.


3M™ Fire Barrier Cast-in Device 2MCID for Metal Pipes, 2 in, 12/case

3M™ Fire Barrier Cast-in Device 2MCID for Metal Pipes, 2 in, 12/case

Intumescent device that firestops 2-inch (50.8 mm) metallic penetrations through fire-rated concrete floor assemblies. The device is installed by attaching directly to the form before a concrete slab is poured. Creates an opening through which mechanical, electrical or plumbing penetrants can be routed after the slab is cured and forms are removed. Provides up to 3-hour fire protection.

3M™ Fire Barrier Cast-In Device 2PCID for Plastic Pipes, 2 in, 12/case

3M™ Fire Barrier Cast-In Device 2PCID for Plastic Pipes, 2 in, 12/case

Intumescent device that firestops 2-inch (50.8 mm) non-metallic penetrations through fire-rated concrete floor assemblies. The device is installed by attaching directly to the form before a concrete slab is poured. Creates an opening through which mechanical, electrical or plumbing penetrants can be routed after the slab is cured and forms are removed. Provides up to 3-hour fire protection.


3M™ Fire Barrier Cast-in Device 3MCID for Metal Pipes, 3 in, 12/case

3M™ Fire Barrier Cast-in Device 3MCID for Metal Pipes, 3 in, 12/case

Intumescent device that firestops 3-inch (76.2 mm) metallic penetrations through fire-rated concrete floor assemblies. The device is installed by attaching directly to the form before a concrete slab is poured. Creates an opening through which mechanical, electrical or plumbing penetrants can be routed after the slab is cured and forms are removed. Provides up to 3-hour fire protection.

3M™ Fire Barrier Cast-In Device 3PCID for Plastic Pipes, 3 in, 12/case

3M™ Fire Barrier Cast-In Device 3PCID for Plastic Pipes, 3 in, 12/case

Intumescent device that firestops 3-inch (76.2 mm) non-metallic penetrations through fire-rated concrete floor assemblies. The device is installed by attaching directly to the form before a concrete slab is poured. Creates an opening through which mechanical, electrical or plumbing penetrants can be routed after the slab is cured and forms are removed. Provides up to 3-hour fire protection.


3M™ Fire Barrier Cast-in Device 4MCID for Metal Pipes, 4 in, 6/case

3M™ Fire Barrier Cast-in Device 4MCID for Metal Pipes, 4 in, 6/case

Intumescent device that firestops 4-inch (101.6 mm) metallic penetrations through fire-rated concrete floor assemblies. The device is installed by attaching directly to the form before a concrete slab is poured. Creates an opening through which mechanical, electrical or plumbing penetrants can be routed after the slab is cured and forms are removed. Provides up to 3-hour fire protection.

3M™ Fire Barrier Cast-In Device 4PCID for Plastic Pipes, 4 in, 6/case

3M™ Fire Barrier Cast-In Device 4PCID for Plastic Pipes, 4 in, 6/case

Intumescent device that firestops 4-inch (101.6 mm) non-metallic penetrations through fire-rated concrete floor assemblies. The device is installed by attaching directly to the form before a concrete slab is poured. Creates an opening through which mechanical, electrical or plumbing penetrants can be routed after the slab is cured and forms are removed. Provides up to 3-hour fire protection.



The devices are installed before the concrete is poured and attached directly to the wood forms. Up to 3 hours of fire protection.

After the concrete cures a pipe is passed through the firestop cast-in device. There is no need for additional steps to firestop with caulk, wrap strip etc. It is one-step firestopping. The line consists of 2", 3" and 4" diameter (8-inch tall) devices for both metallic and nonmetalic pipe penetrations up to three hours in concrete as thin as 2.5". There are also accessories for fluted deck applications and a height adaptor to accommodate pours up to 12".


Title Content Type File Type Size

3M Fire Barrier Cast-In Device

Data Sheet

PDF

63 KB

3M™ Fire Barrier Cast-In Devices

Flyer

PDF

560 KB

Cast-In Device Height Adapter

Data Sheet

PDF

208 KB

Cast-In Device Metal Deck Adapter

Data Sheet

PDF

668 KB

Cast-In Device Tub Box

Data Sheet

PDF

308 KB

Title Content Type File Type Size