| Product Catalog for Government Solutions > Emergency Preparedness, Response & Recover > 1. Emergency Preparedness > Fire Protection Products > |
Fire Barrier Cast-In Devices |
|
|||||
3M™ Cast-In Height AdaptorUsed in conjunction with a 6-inch 3M™ Fire Barrier Cast-In Device. Increases the height of allowable concrete thicknesses by 4 in. (101.6 mm) for installations requiring up to 12 in. (304.8 mm) pour depths. 3M™ Fire Barrier Cast-in Device 2MCID for Metal Pipes, 2 in, 12/caseIntumescent device that firestops 2-inch (50.8 mm) metallic penetrations through fire-rated concrete floor assemblies. The device is installed by attaching directly to the form before a concrete slab is poured. Creates an opening through which mechanical, electrical or plumbing penetrants can be routed after the slab is cured and forms are removed. Provides up to 3-hour fire protection. 3M™ Fire Barrier Cast-In Device 2PCID for Plastic Pipes, 2 in, 12/caseIntumescent device that firestops 2-inch (50.8 mm) non-metallic penetrations through fire-rated concrete floor assemblies. The device is installed by attaching directly to the form before a concrete slab is poured. Creates an opening through which mechanical, electrical or plumbing penetrants can be routed after the slab is cured and forms are removed. Provides up to 3-hour fire protection. 3M™ Fire Barrier Cast-in Device 3MCID for Metal Pipes, 3 in, 12/caseIntumescent device that firestops 3-inch (76.2 mm) metallic penetrations through fire-rated concrete floor assemblies. The device is installed by attaching directly to the form before a concrete slab is poured. Creates an opening through which mechanical, electrical or plumbing penetrants can be routed after the slab is cured and forms are removed. Provides up to 3-hour fire protection. 3M™ Fire Barrier Cast-In Device 3PCID for Plastic Pipes, 3 in, 12/caseIntumescent device that firestops 3-inch (76.2 mm) non-metallic penetrations through fire-rated concrete floor assemblies. The device is installed by attaching directly to the form before a concrete slab is poured. Creates an opening through which mechanical, electrical or plumbing penetrants can be routed after the slab is cured and forms are removed. Provides up to 3-hour fire protection. 3M™ Fire Barrier Cast-in Device 4MCID for Metal Pipes, 4 in, 6/caseIntumescent device that firestops 4-inch (101.6 mm) metallic penetrations through fire-rated concrete floor assemblies. The device is installed by attaching directly to the form before a concrete slab is poured. Creates an opening through which mechanical, electrical or plumbing penetrants can be routed after the slab is cured and forms are removed. Provides up to 3-hour fire protection. 3M™ Fire Barrier Cast-In Device 4PCID for Plastic Pipes, 4 in, 6/caseIntumescent device that firestops 4-inch (101.6 mm) non-metallic penetrations through fire-rated concrete floor assemblies. The device is installed by attaching directly to the form before a concrete slab is poured. Creates an opening through which mechanical, electrical or plumbing penetrants can be routed after the slab is cured and forms are removed. Provides up to 3-hour fire protection. 3M™ Fire Barrier Cast-in Device 6MCID for Metal Pipes, 6 in, 2/caseIntumescent device that firestops 6-inch (152.4 mm) metallic penetrations through fire-rated concrete floor assemblies. The device is installed by attaching directly to the form before a concrete slab is poured. Creates an opening through which mechanical, electrical or plumbing penetrants can be routed after the slab is cured and forms are removed. Provides up to 3-hour fire protection. 3M™ Fire Barrier Cast-In Device 6PCID for Plastic Pipes, 6 in, 2/caseIntumescent device that firestops 6-inch (152.4 mm) non-metallic penetrations through fire-rated concrete floor assemblies. The device is installed by attaching directly to the form before a concrete slab is poured. Creates an opening through which mechanical, electrical or plumbing penetrants can be routed after the slab is cured and forms are removed. Provides up to 3-hour fire protection. 3M™ Fire Barrier Cast-in Device Height Adaptor 2HA, 2 in, 12/caseUsed in conjunction with a 2-inch 3M™ Fire Barrier Cast-In Device. Increases the height of allowable concrete thicknesses by 4 in. (101.6 mm) for installations requiring up to 12 in. (304.8 mm) pour depths. 3M™ Fire Barrier Cast-in Device Height Adaptor 3HA, 3 in, 12/caseUsed in conjunction with a 3-inch 3M™ Fire Barrier Cast-In Device. Increases the height of allowable concrete thicknesses by 4 in. (101.6 mm) for installations requiring up to 12 in. (304.8 mm) pour depths. 3M™ Fire Barrier Cast-in Device Height Adaptor 4HA, 4 in, 12/caseUsed in conjunction with a 4-inch 3M™ Fire Barrier Cast-In Device. increases height of allowable concrete thicknesses by 4 in. (101.6 mm) for installations requiring up to 12 in. (304.8 mm) pour depths. 3M™ Fire Barrier Cast-in Device Metal Deck Adaptor 2MDA, 2 in, 12/caseUsed in conjunction with a 2-inch (50.8 mm) 3M™ Fire Barrier Cast-In Device. Allows the device to be installed on fluted metal decks (requires a minimum 2-1/2 in. (63.5 mm) concrete topping). 3M™ Fire Barrier Cast-in Device Metal Deck Adaptor 3MDA, 3 in, 12/caseUsed in conjunction with a 3-inch (76.2 mm) 3M™ Fire Barrier Cast-In Device. Allows the device to be installed on fluted metal decks (requires a minimum 2-1/2 in. (63.5 mm) concrete topping). 3M™ Fire Barrier Cast-in Device Metal Deck Adaptor 4MDA, 4 in, 12/caseUsed in conjunction with a 4-inch (101.6 mm) 3M™ Fire Barrier Cast-In Device. Allows the device to be installed on fluted metal decks (requires a minimum 2-1/2 in. (63.5 mm) concrete topping). 3M™ Fire Barrier Cast-in Device Metal Deck AdaptorUsed in conjunction with a 6-inch (152.4 mm) 3M™ Fire Barrier Cast-In Device. Allows the device to be installed on fluted metal decks (requires a minimum 4-1/2 in. (114.3 mm) concrete topping). 3M™ Fire Barrier Cast-In Tub Box Assembly 3TB, Foam, 3 in, 6/caseCreates a void on the top surface of a concrete slab for plumbing access. Fastens directly to a 2-inch (50.8 mm) 3M™ Fire Barrier Cast-In Device for Metallic Pipes. Remove 3-inch (76.2 mm) foam insert after slab is cured to create 3 in. (76.2 mm) deep void. |
| Title | Content Type | File Type | Size |
|---|
| Title | Content Type | File Type | Size |
|---|
