Skip to Primary Navigation Skip to Site Navigation Skip to Main Content
3M Government Solutions

Product Catalog for Government Solutions > Medical Center Products > Biomedical Electrodes > Repositionable Electrode > 

3M™ Red Dot™ Repositionable Monitoring Electrodes


3M™ Red Dot™ Repositionable Monitoring Electrodes
Click to Enlarge

These electrodes are designed with a larger conductive area to improve trace quality by reducing ECG artifact. They’re repositionable once upon initial application allowing the electrodes to be moved rather than replacing them with new ones.


3M™ Red Dot™ Repositionable Monitoring Electrode 2660-3

3M™ Red Dot™ Repositionable Monitoring Electrode 2660-3

Electrode area 1.56 inch x 1.25 inch (4cm x 3,2cm) Repositionable Monitoring Electrode, Adhesive area 1.25 inch x 1.25 inch, 3 Each/Bag, 2660 electrode has less aggressive adhesive than the 2670, radiolucent

3M™ Red Dot™ Repositionable Monitoring Electrode 2660-5

3M™ Red Dot™ Repositionable Monitoring Electrode 2660-5

Electrode area 1.56 inch x 1.25 inch (4cm x 3,2cm) Repositionable Monitoring Electrode, Adhesive area 1.25 inch x 1.25 inch, 5 Each/Bag, 2660 electrode has less aggressive adhesive than the 2670, radiolucent


3M™ Red Dot™ Repositionable Monitoring Electrode 2670-3

3M™ Red Dot™ Repositionable Monitoring Electrode 2670-3

Electrode area 1.56 inch x 1.25 inch (4cm x 3,2cm) Repositionable Monitoring Electrode, Adhesive area 1.25 inch x 1.25 inch, 3 Each/Bag, 2670 electrode has a stronger adhesive than the 2660, radiolucent

3M™ Red Dot™ Repositionable Monitoring Electrode 2670-5

3M™ Red Dot™ Repositionable Monitoring Electrode 2670-5

Electrode area 1.56 inch x 1.25 inch (4cm x 3,2cm)Repositionable Monitoring Electrode, Adhesive area 1.25 inch x 1.25 inch, 5 Each/Bag, 2670 electrode has a stronger adhesive than the 2660, radiolucent



Electrodes aren’t always placed where you want them. But now you don’t have to replace an electrode when you only need to reposition it. That’s because, as the name suggests, 3M™ Red Dot™ Repositionable Electrodes 2660 and 2670 can be repositioned once upon initial application. These features could help you save time, reduce waste, increase staff efficiency and potentially cut electrode costs. Other product benefits include a smaller footprint, a comfortable, conformable backing and a higher trace quality, providing an electrode that is up to almost any challenge.

Red Dot Repositionable Electrodes are designed for two levels of adhesion. The 2670 electrode uses an adhesive that is more aggressive than the 2660 adhesive and therefore 2670 should be used if the level of adhesion of the 2660 is too low for a particular patient or clinical application.


Title Content Type File Type Size

Common Questions - Red Dot Repositionable Electrodes

Questions and Answers

PDF

17 KB

Title Content Type File Type Size